ABB ACS2000 User Manual page 92

Medium voltage drives
Hide thumbs Also See for ACS2000:
Table of Contents

Advertisement

92
A C S 2 0 0 0 , 4 K V U S E R M A N U A L
2. To select a function (a blinking cursor indicates
104
the selected function), press the corresponding
Drive selection mode
slow navigation key.
3. To enter the contrast setting function, press the
ENTER key.
4. To change the contrast value, press the
corresponding slow navigation key.
5. To accept the selection and to return to the
actual signal display mode, press the ENTER key.
1 L ->
0.0 rpm
UPLOAD
<= <=
DOWNLOAD
=> =>
CONTRAST
4
1 L ->
0.0 rpm
CONTRAST
[4]
1 L ->
0.0 rpm
CONTRAST
[6]
1 L ->
0.0 rpm
UPLOAD
<= <=
DOWNLOAD
=> =>
CONTRAST
6
6. To cancel the setting and keep the original
selection, press any of the mode keys. The selected
CDP control panel mode is entered.
1 L ->
UPLOAD
DOWNLOAD
CONTRAST
Drive selection mode
Overview
The drive selection mode is used to connect the
CDP control panel to either the AMC (Application
and Motor Controller) circuit board of the AFE
(Active Front End) or the INU (INverter Unit)
of the drive.
Note: In this context, the AMC circuit board
of the AFE and INU is referred to as a drive
that is identified in the control system by
its ID number:
• ID number of INU: 1
• ID number of AFE: 2
ACS2000AFE
4k SingleINU
LDAI5500
ID-Number
1
104
0.0 rpm
<= <=
=> =>
6
Status line
Device type
Application SW
version
Parameter value
Selects the drive
mode
Acknowledges the
selection
Selects the AMC
circuit board (AFE
or INU)