90
A C S 2 0 0 0 , 4 K V U S E R M A N U A L
When the parameter mode is entered for the first
102
time after the auxiliary voltage of the drive has
Parameter mode
been switched on, the display will show the first
parameter of parameter group 11. After that, the
previously selected parameter is shown when
the parameter mode is selected.
Some parameter values cannot be changed while
the drive is running. If this is attempted, the
following warning will be displayed:
** WARNING **
WRITE ACCESS DENIED
PARAMETER SETTING
NOT POSSIBLE
1 L ->
77 SYSTEM CONFIG
01 INU IdentifySel
INU1 (MASTER)
102
Status line
Group number and
name
Parameter number
and name
600.0 rpm
Parameter value
Selects the
parameter mode
Enters change
mode.
Acknowledges the
selection
Selects the
parameter value
Selects the
parameter number
and name
Setting parameters procedure
1. To enter the parameter mode, press the PAR key.
1 L ->
22 RAMP FUNCTIONS
01 ACCDEC 1/2 SEL
ACC/DEC 1
2. To select a different group, press the
corresponding fast navigation key.
1 L ->
21 START/STOP MCB FUNC
01 START FUNCTION
CNST DC MAGN
3. To select a parameter, press the corresponding
slow navigation key.
1 L ->
21 START/STOP MCB FUNC
07 PROCESS STOP MODE
STOP RAMP
4. To enter the parameter setting function, press
the ENTER key.
1 L ->
21 START/STOP MCB FUNC
07 PROCESS STOP MODE
[STOP RAMP]
600.0 rpm
600.0 rpm
600.0 rpm
600.0 rpm

Hide quick links: