c d p c o n T r o l pa n e l
5. To change the parameter value, press:
103
• The corresponding slow navigation key for
Function mode
numbers and text
• The corresponding fast navigation key for
numbers only
6. To accept the selection and to return to the
actual signal display mode, press the ENTER key.
7. To cancel the setting and keep the original
selection, press any of the mode keys. The
selected CDP control panel mode is entered.
Parameter lock
Unauthorized parameter entry can be prevented
by activating the ParameterLock function in
parameter group 16 SYSTEM CTRL INPUTS.
The ParameterLock is activated by setting
parameters 16.02 and 16.03 accordingly.
Activating the ParameterLock
1. Select parameter 16.02 PARAMETER LOCK.
2. Set parameter 16.02 to LOCKED.
3. Save the setting and exit the parameter mode.
1 L ->
600.0 rpm
21 START/STOP MCB FUNC
07 PROCESS STOP MODE
[COAST STOP]
1 L ->
600.0 rpm
21 START/STOP MCB FUNC
07 PROCESS STOP MODE
COAST STOP
1 L ->
600.0 rpm
21 START/STOP MCB FUNC
07 PROCESS STOP MODE
STOP RAMP
Opening the ParameterLock
1. Select parameter 16.03 PASSCODE.
2. Set the correct pass code.
3. Save the setting and exit the parameter mode.
See Appendix M - Signal and parameter
table, located on the CD, for further
information.
Function mode
Overview
The function mode is used to set the display
contrast.
1 L ->
0.0 rpm
UPLOAD
<= <=
DOWNLOAD
=> =>
CONTRAST
4
103
Setting functions procedure
1. To enter the function mode, press the FUNC key.
1 L ->
UPLOAD
DOWNLOAD
CONTRAST
91
Status line
Selectable
functions
Selects the
function mode
Acknowledges
the selection
Selects the line
0.0 rpm
<= <=
=> =>
4