:MARKer Commands

Parameter Suffix
Parameter Suffix
Keysight M8121A Arbitrary Waveform Generator User Guide
[:SOURce]:MARKer[1|2]:SAMPle:VOLTage[:LEVel][:IMMediate]:AMPLitude[?] <level>
Command
:MARK:SAMP:VOLT:AMPL[?]
Long
:MARKer:SAMPle:VOLTage:AMPLitude[?]
Parameters
<level>
None
Description
Set or query the output amplitude for sample marker.
Examples
Command
:MARK:SAMP:VOLT:AMPL 3.0e-9
Query
:MARK:SAMP:VOLT:AMPL?
[:SOURce]:MARKer[1|2]:SAMPle:VOLTage[:LEVel][:IMMediate]:HIGH[?] <level>
Command
:MARK:SAMP:VOLT:HIGH[?]
Long
:MARKer:SAMPle:VOLTage:HIGH[?]
Parameters
<level>
None
Description
Set or query the output high level for sample marker.
Examples
Command
:MARK:SAMP:VOLT:HIGH 1.5
Query
:MARK:SAMP:VOLT:HIGH?