Remote Programming
Parameter Suffix
Parameter Suffix
88
[:SOURce]:MARKer[1|2]:SAMPle:VOLTage[:LEVel][:IMMediate]:LOW[?] <level>
Command
:MARK:SAMP:VOLT:LOW[?]
Long
:MARKer:SAMPle:VOLTage:LOW[?]
Parameters
<level>
None
Description
Set or query the output low level for sample marker.
Examples
Command
:MARK:SAMP:VOLT:LOW -0.5
Query
:MARK:SAMP:VOLT:LOW?
[:SOURce]:MARKer[1|2]:SAMPle:VOLTage[:LEVel][:IMMediate]:OFFSet[?] <level>
Command
:MARK:SAMP:VOLT:OFFS[?]
Long
:MARKer:SAMPle:VOLTage:OFFSet[?]
Parameters
<level>
None
Description
Set or query the output offset for sample marker.
Examples
Command
:MARK:SAMP:VOLT:OFFS 2.5e-9
Query
:MARK:SAMP:VOLT:OFFS?