Label Gap Sensor - Digi 700 Series Service Manual

Weigh labeller
Table of Contents

Advertisement

Label Gap sensor

The label gap sensor detects the label and the gap between labels to obtain the correct label feed out
length.
Both the sensor parts are mounted into an upper & lower bracket with a fixed position mounted behind the
thermal head.
It is important to ensure this area is kept clean and free from any debris of label/dirt which will cause the
sensor to incorrectly detect.
The label position can be affected by two distance settings in the service menu / labeller setup / service /
settings (for Worldview software)
Labeller type
Signature R-L
near edge
Head to bar
4
distance (mm)
Gap to head
67
distance (mm)
Signature L-R
Signature R-L
near edge
platen roller
4
11
74
60
HI, MI, WI-700 service manual - 2 - component parts
Signature labeller type
shown
The gap to head distance setting is the
distance the label gap sensor is from the
thermal head.
The head to bar distance is the distance
from thermal head to stripping bar edge
Note: for a Signature labeller the gap to
head distance differs depending on L-R
or R-L flow. Also it will change if Platen
roller kit is used instead of the near
edge kit
The figures in the chart below are the
default values, these may need to be
adjusted depending on the fixed
position of the gap sensor assembly to
the back-plate
Signature L-R
platen roller
11
67
2-51
Classic
10
95
Issue 9 04/2020