Labeller Board - Digi 700 Series Service Manual

Weigh labeller
Table of Contents

Advertisement

Labeller board

Take up motor
torque setting.
Solenoid
valves/ fans /
take-up
motor
Stepper
motor
connection
Power from
labeller PSU's
Notes:
The IP address is always in the range 192.168.0.xx The xx being which labeller it will be fitted into
(e.g.-labeller 1 has 1, labeller 2 has 2.
The last IP segment is set with the rotary switch on the board. The board is pre-set with 192.168.0.
The rotary switch then sets the labeller number.
J5 label gap sensor jumpers – This jumper adjusts the sensor reading value of the gap sensor – for
more detail on this refer to gap sensor section. On Signature labellers, an additional sensor I/F board
is fitted for sensor adjustment - see following page, therefore adjustment of this jumper is not
normally required.
(Note: the second set of jumpers, J6 are not used).
There are three connections on the board to allow software updates onto the board. This process
can also be carried out within the machine software (service settings) via Ethernet download
For software
Label feed
programming
button and
(print side) -
red/green
also see note
LED's
Thermal
head power
HI, MI, WI-700 service manual - 2 - component parts
Gap sensor.
8pin connector
Power reset
Dip switches -
button
not normally
required
2-44
J5 – label
gap sen-
For software
sor value
programming
adjust –
- also see
see note
note
below
Thermal head
ribbon. 26pin
connector
Labeller IP
address setting.
See note below
For software
programming
(comms
side) - also
see note
Ethernet
comms from
console.
Issue 9 04/2020

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hi-700Hi-700 evoHi-700wMi-700Wi-700

Table of Contents