End Stop Cushioning; Air Pressure / Vacuum - Digi 700 Series Service Manual

Weigh labeller
Table of Contents

Advertisement

Servicing & adjustments
End of stroke air cushion adjustment
Air pressure & vacuum adjustment
HI, MI, WI-700 service manual - 4 –servicing
Damping for each end of the cylinder travel can be
adjusted to obtain the required amount to cushion the
end stop
With the top cover removed the air cylinder is visible
Using a small hex key the end of the cylinder, turn
the screw to adjust amount of cushioning
With the top cover removed, the two air
regulators are visible
Vacuum pressure - adjust the regulator
marked 'VAC' - typical pressure =
0.15MPa
Cylinder pressure - adjust the regulator
marked 'CYL' - typical pressure =
0.15MPa
4-106
Issue 9 04/2020

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hi-700Hi-700 evoHi-700wMi-700Wi-700

Table of Contents