Proximity Sensor; Software Settings - Digi 700 Series Service Manual

Weigh labeller
Table of Contents

Advertisement

Servicing & adjustments
Proximity sensor operation
The proximity sensor mounted behind the applicator shoe detects when the applicator shoe has reached
the package to apply the label. When the shoe pushes against the package, it will push back on the spring
loaded mount, the pushed back position is detected by the proximity sensor which in turn retracts the
cylinder.
Package pushing
applicator shoe
back
HI, MI, WI-700 service manual - 4 –servicing
Cylinder movement
Applicator shoe movement. Shoe will be pushed back
against spring pressure to activate the proximity
sensor

Proximity sensor

Proximity sensor activated (orange indicator light
comes on)
4-108
The sensor must be is
adjusted correctly to ensure
the rear of the applicator
shoe activates the sensor
when pushed back
Adjust depth of proximity
sensor on thread
Software timing - refer to
the following page for

software settings

Issue 9 04/2020