Check Current Status Icons; Figure 7: Login; Figure 8: Status Icons - Baicells Atom ID0406-6.5 User Manual

Indoor cpe
Hide thumbs Also See for Atom ID0406-6.5:
Table of Contents

Advertisement

Figure 7: Login

6.2 Check Current Status Icons

As shown in Figure 7 above, the GUI home page is the Status > Overview window. This page displays the
at-a-glance CPE Current State icons at the top of the window, as shown in Figure 8. These fields give a quick
indication if anything is wrong with basic CPE operation.

Figure 8: Status Icons

Connection State - The possible connection states are Checking SIM, Scanning, Registering,
Acquiring IP, Connected, or Disconnected. If the CPE is checking SIM, scanning, registering, or
acquiring an IP address, it means the CPE is in the process of establishing a connection. Give it a
few moments to finish its connection process, and then check if the status is Connected. Otherwise,
make sure the CPE is installed properly and powered on.
Signal Intensity - The possible states are No Signal, Severe, Bad, Good, or Excellent (CAT4)/Strong
(CAT6/7). Check that the signal is indicated as either Good or Excellent/Strong. If the Atom unit
cannot detect a wireless signal, or if the signal is very weak, try moving the unit closer to a window,
higher up, and away from any other devices using radio frequency, or away from objects that may
be blocking the signal between the CPE and the eNB. Otherwise, contact your service provider for
assistance.
7

Advertisement

Table of Contents
loading

Table of Contents