Aurora243 Outdoor 2x10W TDD gNodeB Installation Guide
3.4.7.4 Power Adapter Grounding (Optional)
The power adapter grounding terminal should connect to the grounding bar through the ground wire and
adhere to local standards (Figure 3-23).

Figure 3-23: Power Adapter Grounding

3.5 Maintenance Chamber Waterproofing

Once the installation is complete, you must close the maintenance chamber of the equipment and
waterproof the chamber.
1. Clamp the power cord to the wire position and seal the wire diameter 0.35 inches ± 0.04 inches
(9 mm
1 mm).
±
2. Put the Ethernet cable on the wire and seal the wire diameter 0.28 inches
(7 mm
1 mm).
±
3.6 Power on to Check the LED Status
After the Aurora243 is powered on, check that the LED indicators are lighting as expected, as described in
Table 2-3
(section
2.2).