7.2 Check Current Status Icons

As shown in Figure 27 above, the GUI home page is the Status > Overview window. This page displays the
at-a-glance CPE Current State icons at the top of the window, as shown in Figure 28. These fields give a
quick indication if anything is wrong with basic CPE operation.
Figure 28: Status Icons
Connection State - The possible connection states are Checking SIM, Scanning, Registering,
Acquiring IP, Connected, or Disconnected. If the CPE is checking SIM, scanning, registering, or
acquiring an IP address, it means the CPE is in the process of establishing a connection. Give it a
few moments to finish its connection process, and then check if the status is Connected. Otherwise,
make sure the CPE is installed properly and powered on.
Signal Intensity - The possible states are No Signal, Severe, Bad, Good, or Excellent (CAT4)/ Strong
(CAT6/7/15). Check that the signal is indicated as either Good or Excellent/Strong. If the Atom unit
cannot detect a wireless signal, or if the signal is very weak, try moving the unit closer to a window,
higher up, and away from any other devices using radio frequency, or away from objects that may
be blocking the signal between the CPE and the eNB. Otherwise, contact your service provider for
assistance.