SQVEx 05.2
Electrical connection
6.3.

KT/KM electrical connection

Short description
24
SQVEx 14.2/ SQRVEx 05.2
Table 12: Versions of the AUMA plug/socket connector
Electrical con-
Figure
nection
KT
KP
KES
Figure 18: KT/KM electrical connection
[1]
Terminal carrier with screw-type/spring clamp terminals
[2]
Connection frame
Figure shows KT version
KT plug-in electrical connection with screw-type terminals for power connection and
spring clamp terminals for control contacts.
SQRVEx 14.2 Control unit: electronic (MWG)
ACVExC 01.2 Modbus RTU
Properties
Plug-in integral terminal connection
with enlarged terminal compartment
Plug/socket connector with terminal
board
Plug-in terminal connection with en-
larged terminal compartment
For description
and assembly
refer to chapter
page 24,
KT/KM electrical
connection
page 33,
KP/KPH electrical
connection
page 38, KES
electrical connec-
tion