Corrective Action; Faults During Commissioning; Fault Indications And Warning Indications - AUMA SQVEx 05.2 Manual

Part-turn actuators
Hide thumbs Also See for SQVEx 05.2:
Table of Contents

Advertisement

SQVEx 05.2
SQVEx 14.2/ SQRVEx 05.2
ACVExC 01.2 Modbus RTU
12.

Corrective action

12.1.

Faults during commissioning

Table 27:
Faults during operation/commissioning
Fault
Mechanical position indicator cannot
be set.
In spite of correct setting of mechan-
ical limit switching, actuator operates
into the valve or actuator end position.
Actuator operation is too fast or too
slow.
Actuator suddenly stops in end posi-
tions.
12.2.

Fault indications and warning indications

Table 28:
Faults and warnings via status indications in the display
Indication on display
S0001
S0005
Warnings
S0006
Not ready REMOTE
S0007
Fault
S0008
Out of specification
SQRVEx 14.2 Control unit: electronic (MWG)
Description/cause
Reduction gearing is not suitable for actuator swing
angle.
The overrun was not considered when setting the
limit switching.
The overrun is generated by the inertia of both the
actuator and the valve and the delay time of the
actuator controls.
Operating time setting is incorrect.
Velocity reduction switched off or incorrectly set
before reaching end positions.
Faults interrupt or prevent the electrical actuator operation. In the event of a fault,
the display backlight is red.
Warnings have no influence on the electrical actuator operation. They only serve
for information purposes. The display remains white.
Collective signals include further indications. They can be displayed via the
Details push button. The display remains white.
Description/cause
Instead of the valve position, a status text is dis-
played.
Collective signal 02:
Indicates the number of active warnings.
Collective signal 04:
Indicates the number of active signals.
Collective signal 03:
Indicates the number of active faults.
The actuator cannot be operated.
Collective signal 07:
Indication according to NAMUR recommendation
NE 107
Actuator is operated outside the normal operation
conditions.
Remedy
Set gear stage of the reduction gearing.
The control unit might have to be exchanged.
Determine overrun: Overrun = travel covered
from switching off until complete standstill.
Set limit switching again considering the over-
run. (Turn handwheel back by the amount of
the overrun)
Modify operating time.
Modify velocity.
Remedy
For a description of the status texts, refer to Manual
(Operation and setting).
For indicated value > 0: Press push button
tails.
For details, refer to <Warnings and Out of specific-
ation> table.
For indicated value > 0: Press push button
tails.
For details, refer to <Not ready REMOTE and
Function check> table.
For indicated value > 0: Press push button
to display a list of detailed indications.
For details, refer to <Faults and Failure> table.
For indicated value > 0: Press push button
tails.
For details, refer to <Warnings and Out of specific-
ation> table.
Corrective action
De-
De-
Details
De-
77

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sqvex 14.2Sqrvex 05.2Sqrvex 14.2Sqve series