AUMA SQVEx 05.2 Manual page 27

Part-turn actuators
Hide thumbs Also See for SQVEx 05.2:
Table of Contents

Advertisement

SQVEx 05.2
SQVEx 14.2/ SQRVEx 05.2
ACVExC 01.2 Modbus RTU
Information
Information
SQRVEx 14.2 Control unit: electronic (MWG)
5.
Connect cables according to order-related wiring diagram.
Figure 21: Connect cables to terminal carrier
[1]
Fitting control cables into spring clamp terminals
[2]
Tightening power terminals
For service purposes, each spring clamp terminal is equipped with a test contact
located above the numbering.
For flexible cables: for screw-type terminals, use wire end sleeves according to DIN
46228. For spring clamp terminals, connection is possible without wire end sleeves.
Electrical connection
27