Table 31 Upper Limits For Current On The Individual Pins Of The Connections - WAGO 765-1205/0100-0000 Manual

8-channel digital input/output; ethercat; 24 v dc; 2.0 a;
Table of Contents

Advertisement

765-1205/0100-0000
termined by the current load capacity of the pluggable connector on the input supply con-
nection and the PCB. This is max. 16 A. The total current must not exceed this current
load capacity.
Note the following:
1. When using digital outputs, the current feedthrough must be reduced by the current
that flows through these outputs, for example.
2. In the worst case, the permissible current feedthrough may reach a value of 0 A!
3. The passthrough connection between the supply voltage input and output has no in-
ternal protective device against overcurrent!
Therefore, the safety measures given in
(fuse protection, regulated power supply with current limitation and additional monitoring
of the measured values of the sensors) are necessary.
Rule 3: Ports X01, X02 etc.
The following rules apply to each port of the product individually:
Rule 3 – Upper limits for current on the individual pins of the ports
The following upper limits apply to the currents on the pins of the individual ports:
Pin
1
2
3
4
The device is designed in such a way that it can be used in overload operation according
to the following table "Module 0765-1205/0100-0000 – Currents in Supply Cable 1" with-
out time limit. The following applies to all pins:
If the maximum load capacity (upper limit of overload operation) of the pin is exceeded,
there is a risk of destruction of or damage to the pluggable connector or PCB of the de-
vice.
CAUTION
Note significance of pin 3
Note that the sum of the currents of pins 1 and 4 flows to pin 3.
Product-Specific Information
For supply cable 1L of the 0765-1205/0100-0000 Digital Input/Output Module, the cur-
rents declared in the following table must be taken into account:
Current
I
X31_1L
I
X32_1L
I
logic
Product manual | Version: 1.0.0
8DIO FLD EC DC 24V 2.0A
8 Requirements on the Power Supply [} 37]
Table 31: Upper Limits for Current on the Individual Pins of the Connections
Normal Operation
4 A
2 A
4 A
2 A
Table 32: Module 0765-1205/0100-0000 – Currents in Supply Cable 1
Description
Current to connection PWR IN (X31): current 1L+ / reverse current 1L−
Current to connection PWR OUT (X32): current 1L+ / reverse current 1L−
Logic supply
Planning
Overload Operation
4 A
2.4 A
4 A
2.4 A
35

Advertisement

Table of Contents
loading

Table of Contents