Water Monitoring System
MI6100-0005
System Type
Task:
Task
description:
Difficulty 1-5
Spare Parts
Part no:
02342
Instructions
Steps
Note: Make sure the power supply is switched off
prior to replacing the wiper unit.
This is done by switching off the main automatic
fuses found inside the monitoring unit.
Remember to check correct termination prior to
switching power ON. Refer to the illustration (on
the right side)
After installation of the Turbidity Analyzer, the
system must be calibrated following the calibration
instruction in the operation manual.
Notes:
Ver.5.0 – Revision March 2022
Water Monitoring System
Turbidity Analyzer Replacement
This instruction describes the replacement of the Turbidity Analyzer. The
replacement must be carried out by a trained technician.
Overhaul Interval
When necessary
Description:
Turbidity Analyzer
Estimated Time Consumption
30 min
Tools
Qty.
Item:
1
Small size flat headed screwdriver
1 x allen key
2 x 19mm spanners
Photos:
MI6100-0005