Water Monitoring System
MI6100-0021
System Type
Water Monitoring System
Task:
Pump Type B version 2 Replacement
Task
This instruction identifies the replacement of the Pump Type B. Pump Type B
replacement must be carried out by a skilled technician.
description:
Difficulty 1-5
Overhaul Interval
Spare Parts
Part no:
Description:
03613
Pump Type B version 2
Instructions
Note: To avoid damage, it is important
to follow the instructions in this guide,
during pump replacement.
Make sure the power supply is Off
prior to replacing the pump.
Tools to be used:
Hose cutter or knife
Small screwdriver
Allen key
Spanner 13, 19 & 24 mm
A. Disassembly of the existing Pump
1. Disconnect
Pump
Illustration 1.
2. Loosen
Fitting
Illustration 2.
3. Loosen the left bolt & completely
unscrewed & remove right bolt
in Strainer - Illustration 3.
4. Lift PTFE tube carefully without
bending it - Illustration 4.
5. Loosen bolts for the pump &
make sure to support the pump
by hand and keep pump straight to
the backplate to avoid damage of
pump socket - Illustration 5.
6. Lift pump from Fitting Union &
remove the pump.
Ver.5.0 – Revision March 2022
Photos:
Illustration 1
Wires
-
Unions
-
Illustration 3
Illustration 5
Estimated Time Consumption
20 - 30 min
Tools
Qty.
Item:
1
MI6100-0021
Illustration 2
Illustration 4
Page 107 of 110