Software Update - Maritime G6100 Operation Manual

Water monitoring system
Table of Contents

Advertisement

Water Monitoring System

4.2.6 Software Update

1. You will be sent the relevant software by email.
2. The PLC folder and the UpdatePackage Zip folder must be copied to an empty USB-
stick. The content of the USB stick should look like this:
3. Note: the different software is used for different system configurations. The correct
software version can be identified in the Test & configuration sheet.
4. Check that the calibration values on the Test & Configuration Sheet correspond with the
values stored in the system settings. If this is not the case, then carefully write down the
calibration values used for PAH and the Timer settings.
These values can be found in here: Settings —> Setup
• User: service
• Password: 1234
5. Go to the System Info screen and note down the IP-address.
6. Plug the USB-stick into back of the HMI, while power is ON.
7. Press and hold an empty space on the HMI touch screen. Next, select "Update". Select
"Auto Select". Press "Next". Wait for at least 2 minutes.
8. Reboot the system by powering OFF and ON again. Wait for the system to start up.
9. Go to System Info screen and press the "Update software" button – Press "Yes" and wait
for at least 2 minutes.
Ver.5.0 – Revision March 2022
Page 27 of 110