Switching The Gun Types - WAGNER Sprint 60 L XE Operating Manual

Sprint xe series manual powder system
Table of Contents

Advertisement

VERSION 05/2017
OPERATING MANUAL

12.5.2 SWITCHING THE GUN TYPES

Note:
Clean the powder residues from all powder-conveying parts thoroughly, before changing
to another gun type.
1
P_02719
Procedure:
(For example: switching from Corona to Tribo)
1. Switch off control unit with switch 1 on the rear or with "Standby" button 15 on the
front.
2. Change the coating powder from Corona to Tribo.
3. Disconnect the hose (2) (transparent, atomizing air) from the Corona gun and
connect it to the Tribo gun (Tribo air).
4. Disconnect the powder feed hose of the Corona spray gun from the powder injector
and connect the Tribo gun hose to the powder injector.
5. Set the switch (C) on the switchbox to Tribo.
6. Switch on control unit with switch 1 on the rear or with "Standby" button 15 on the
front.
Note:
Parameter C11, in the EPG-Sprint XE control unit device confi guration, must be set to
"aut". No gun is selected at fi rst after the control unit is switched on. This will however be
automatically selected and displayed after 1 second.
ORDER NUMBER DOC 2354920
30
20
10
2
P_01785
50
60
40
3
m /h
70
Ø
Tri
5.5
3.0
12
1.5
4.5
11
80
0.5
3.5
10
9
0.3
2.5
8
90
0.1
2.0
100
%
0
%
SP RI N T X
EPG
SPRINT XE
61