Panel Alarm

• Select the Panic option to enable panel alarms. An
alarm is triggered when the 'REC' button on the
touch screen monitor is pressed.
• Alarm type: Select either Sensor (When a Sensor
alarm is triggered, it is recorded in video as
metadata only), or Event (When an Event alarm is
triggered, it marks recorded video as 'Alarm Video'
with metadata included).
• Trigger: Tap the Setup button to configure the
parameters specific to this type of alarm (see
Trigger Setup below)
• Linkage: Tap the Setup button to configure the
recording, monitor display and additional options
specific to this type of alarm (see Linkage Setup below)
Then tap the Save button.
Trigger Setup
Tap the Setup button under the Trigger field to display
the setup screen to configure the parameters specific to
the Panel Alarm.
• Any key: Enter a time (between 1 and 255 seconds)
that the 'REC' button on the touch screen monitor
must be pressed and held down for to trigger the
alarm
• Effective Time: Enter the time (between 0 and
10 seconds) that the alarm is effective (select the
Question Mark icon for more details)
Then tap the OK button.
Then tap the Save button.