[:SOURce<hw>]:BB:DVBC:TSPacket <SetTSPacket>
Specifies the structure of the test transport stream packet that is fed to the modulator.
Parameters:
<SetTSPacket>
Example:
Manual operation:
[:SOURce<hw>]:BB:DVBC:PIDTestpack <SetPIDTestpack>
If a header is present in the test packet ("Test TS Packet > Head/184 Payload"), you
can specify a fixed or variable packet identifier (PID).
Parameters:
<SetPIDTestpack>
Example:
Manual operation:
[:SOURce<hw>]:BB:DVBC:PID <SetPID>
Sets the PID.
Parameters:
<SetPID>
Example:
Manual operation:
[:SOURce<hw>]:BB:DVBC:PAYLoad <SetPayload>
Defines the payload area content of the
Parameters:
<SetPayload>
User Manual 1179.4686.02 ─ 01
H184 | S187
H184
Head/184 Payload
S187
Sync/187 Payload
*RST:
H184
See
Example "Configuring test signal properties"
See
"Test TS Packet"
on page 16
NULL | VARiable
*RST:
NULL
See
Example "Configuring test signal properties"
See
"PID Test Packet"
integer
Range:
0 to 8191
*RST:
8191
See
Example "Configuring test signal properties"
See
"PID (Hex)"
on page 17
TS
packet.
PRBS | H00 | HFF
PRBS
PRBS data in accordance with