Omron H3CR-A Manual page 45

Hide thumbs Also See for H3CR-A:
Table of Contents

Advertisement

H3CR-G
Time Ranges
Star-delta transfer
time
Star
6
0.5 to 6 sec
operation
ti
12
1 to 12 sec
time setting
time setting
60
5 to 60 sec
120
10 to 120 sec
Ratings
Rated supply voltage
Operating voltage range
Power reset
Power consumption
Control outputs
Characteristics
Accuracy of operating time
Setting error
Star-delta transfer time
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Case color
Enclosure ratings
Weight
0.05 sec
0.1 sec
100 to 120 VAC (50/60 Hz), 200 to 240 VAC (50/60 Hz)
85% to 110% of rated supply voltage
Minimum power-opening time: 0.5 s
100 to 120 VAC: approx. 6 VA/2.4 W
200 to 240 VAC: approx. 12 VA/2.6 W
Contact output: 5 A at 250 VAC, resistive load (cos% = 1)
+0.3% FS max.
+5% FS +0.05 s max.
Accuracy: !25% FS + 5 ms max.
+0.5% FS max.
+2% FS max.
100 MW min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed
non-current-carrying metal parts)
2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
3 kV (between power terminals)
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts)
+1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width:
100 ns/1 ms, 1-ns rise)
Malfunction:8 kV
Destruction: 15 kV
Destruction:10 to 55 Hz with 0.75-mm single amplitude each in three directions
Malfunction:10 to 55 Hz with 0.5-mm single amplitude each in three directions
2
Destruction: 980 m/s
(100G) each in three directions
2
Malfunction:294 m/s
(30G) each in three directions
Operating:--10%C to 55%C (with no icing)
Storage: --25%C to 65%C (with no icing)
Operating: 35% to 85%
Mechanical:20 million operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)
Light Gray (Munsell 5Y7/1)
IEC: IP40
H3CR-G8L: approx. 110 g; H3CR-G8EL: approx. 130 g
0.25 sec
0.5 sec
H3CR-G
45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents