Nomenclature
Front Panel (With Cover Open)
12. OUT ON/OFF
Switch
Time adjustment
mode indicator
Power failure
indicator
Output
Output indicator
Key Operations
No.
1
Shifts the cursor (B) specifying a day to the right.
2
Sets or cancels a specified day.
3, 4
Sets a time or ON/OFF time width.
5
Monitors the parameters set for an operation during an operation.
6
Sets parameters.
7
Sets a time adjustment mode.
8
Specifies a cyclic operation, or sets a pulse width.
9
Specifies a day substitution operation.
10
Cancels the parameters set for each circuit, or a day override operation.
11
P1:
Circuit 1 setting mode
P2:
Circuit 2 setting mode
RUN: RUN mode
12
ON:
Turns on the output regardless of the setting.
AUTO: Execute an operation as specified.
OFF:
Turns off the output regardless of the setting.
13
TIMER: Executes an ordinary timer or cyclic operation.
PULSE: Executes a pulse output operation.
14
Specifies an operation to be performed after power recovery (AUTO/MANUAL).
14. Boot selection
13. Output setting switch
Timing chart
display
Automatic operation
indicator
1. Shift Key
2. Set/Reset Key
3. h (hour) Key
4. m (minute) Key
5. Check Key
6. Write Key
11. Mode Switch
7. Time (time adjustment) Key
10. Clr (clear) Key
9. Copy Key
8. Cycle/Pulse Key
(Actual size)
Current day/operation day indicators
Display of current time/operation time/time width
Pulse width unit indicator
Display of number of remaining steps
Circuit
Circuit number
indicators
Function
H5S