H2A
Hold-down Clips (Attached)
PHC-1 For PF085A
Installation
Terminal Arrangement
H2A
Precautions
Mounting
When two or more timers are to be mounted in line, provide a dis-
tance of more than 5 mm between the two adjacent timers.
When two or more timers mounted in line are to be continuously en-
ergized at the same time after the set time has elapsed, be sure to
limit the carry current to less than 1 A.
When using the timers at an ambient temperature of more than
40"C, be sure to reset the timers immediately after the set time has
elapsed.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. L04-E1-8
H2A-H
Wiring
When wiring, employ a multi-core cable having a finished outer di-
ameter of less than 10.5 mm, or insulated (twisted) wires with less
than a 3 mm outer diameter.
H2A
223