Precautions
Operation
If two or more ON or OFF times have been specified at the same
time, the first input ON time or the last input OFF time take prece-
dence over the other ON or OFF times.
Note: With the above setting, the output is continuously produced
without interruption, because the ON time of program 1 and
OFF time of program 2 are valid.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. L15-E1-3
240
The ON and OFF times can be set to the same value, but the timer
will not operate.
(Example: if both the ON and OFF times are set to 10:30 a.m.,
Monday, the timer does not produce any output.)
After data has been set, note that pressing the TMR/
change the operation between the timer and pulse operation will
cause the set data to be lost.
If a power failure occurs, the output is turned off and the indicators
go off during the power failure.
WARNING
!
The H5F has a built-in lithium battery. When disposing of an
entire timer containing a lithium battery, be sure to do so prop-
erly. Lithium batteries may explode if incinerated, causing fire
or severe burns.
Also, do not touch the input terminals of any H5F timer while
power is being to the timer.
H5F
key to
P