H5CL
Characteristics
Item
Deviation of operating time and
setting error (including temperature
and voltage influences)
Insulation resistance
Dielectric strength
Surge voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Weight
Note: 1. The values are based on the set value.
2. The value is applied for a minimum pulse width of 1 ms.
Nomenclature
Indicator
1. Present Value
Red LEDs with a character height of 12 mm
Note: The decimal point will flash on the present value dur-
ing the timing operation in the following ranges:
0.1 to 999.9 min, 0 h 01 min to 99 h 59 min, and
0.1 to 999.9 h.
2. Preset Value
Green LEDs with a character height of 8 mm
3. Reset Indicator (orange)
4. Key Protection Indicator (orange)
5. Time Unit Display (orange)
6. Control Output Indicator (orange)
Operation Key
7. Reset (RST) Key
The RST Key initializes the present value and control output.
8. Increment Keys (1 to 4)
Up Keys 1 to 4 increment the preset value.
9. Decrement Keys (1 to 4)
Down Keys 1 to 4 decrement the preset value.
H5CL-Aj (AC models)
Power start: !0.01% !0.05 s max. (see note 1)
Signal start: !0.005% !0.03 s max. (see note 1)
Signal start, at transistor output model: !0.005% !3 ms max. (see note 1 and 2)
If the set value is within the sensor waiting time (250 ms max.) in the case of power start, the
control output of the H5CL will not be turned ON until the sensor waiting time passes.
100 M$ min. (at 500 VDC) (between current-carrying terminal and exposed
non-current-carrying metal parts, and between non-continuous contacts)
2,000 VAC, 50/60 Hz for 1 min (between
current-carrying terminal and exposed
non-current-carrying metal parts)
1,000 VAC, 50/60 Hz for 1 min (between
non-continuous contacts)
3.0 kV (between power terminals)
4.5 kV (between current-carrying terminal and
exposed non-current-carrying metal parts)
!1.5 kV (between power terminals)
!600 V (between input terminals),
square-wave noise by noise simulator (pulse
width: 100 ns/1 &s, 1-ns rise)
Destruction:
15 kV
Malfunction:
8 kV
Destruction:
10 to 55 Hz, 0.75-mm single amplitude each in three directions
Malfunction:
10 to 55 Hz, 0.5-mm single amplitude each in three directions
2
Destruction:
294 m/s
(30G) each in three directions
2
Malfunction:
98 m/s
(10G) each in three directions
--10 to 55 "C (--10 to 50 "C if timers are mounted side by side) (with no icing)
Operating:
--25 to 65 "C (with no icing)
Storage:
Operating: 35% to 85%
Mechanical:
10,000,000 operations min.
Electrical:
100,000 operations min. (3 A at 250 VAC, resistive load)
Approx. 130 g
H5CL-ADj (DC models)
1,000 VAC, 50/60 Hz for 1 min (between
current-carrying terminal and exposed
non-current-carrying metal parts, and
between non-continuous contacts)
1.0 kV (between power terminals)
1.5 kV (between current-carrying terminal and
exposed non-current-carrying metal parts)
!480 kV (between power terminals)
!600 V (between input terminals),
square-wave noise by noise simulator (pulse
width: 100 ns/1 &s, 1-ns rise)
Approx. 110 g
Stick the enclosed label here.
6
3
7
4
H5CL
1
2
5
8
9
153