New H3Y
Engineering Data
H3Y-2, H3Y-2-0
250 VAC, cos% = 1
24 VDC, cos% = 1
Load current (A)
Reference: A maximum current of 0.6 A can be switched at 125 VDC (cos% = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases,
a life of 100,000 operations can be expected.
The minimum applicable load is 1 mA at 5 VDC (P reference value).
H3Y-4, H3Y-4-0
250 VAC, cos% = 1
24 VDC, cos% = 1
Load current (A)
Reference: A maximum current of 0.5 A can be switched at 125 VDC (cos% = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases,
a life of 100,000 operations can be expected.
The minimum applicable load is 1 mA at 1 VDC (P reference value).
Operation
Timing Chart
H3Y-2, H3Y-2-0
NC
126
H3Y-2, H3Y-2-0
250 VAC, cos% = 0.4
24 VDC, L/R = 7 ms
Load current (A)
H3Y-4, H3Y-4-0
250 VAC, cos% = 0.4
24 VDC, L/R = 7 ms
Load current (A)
H3Y-4, H3Y-4-0
NC
New H3Y