Omron H3CR-A Manual page 161

Hide thumbs Also See for H3CR-A:
Table of Contents

Advertisement

H5BR
Ratings
Rated supply voltage
Operating voltage range
Power consumption
Reset and control signals
Batch count reset and gate
Key protect
One-shot time
Power reset (except A-3, b-1, and F mode)
Signal, reset, gate, batch count reset inputs
Key protect input
Control outputs
External power supply
Ambient temperature
Storage temperature
Ambient humidity
Case
Characteristics
Repeat accuracy, setting error (including
temperature and voltage effects)
Insulation resistance
Dielectric strength
Surge voltage
Noise immunity
Static immunity
Vibration
Shock
Life expectancy
Weight
100 to 240 VAC, 50/60 Hz
24 VAC/12 to 24 VDC (permissible ripple: 20% max.)
85% to 110% of rated voltage
Approx. 8 VA at 50 Hz, 240 VAC; approx. 5 W at 24 VDC
Min. pulse width 1 ms/20ms selectable
Min. pulse width: Approx. 20 ms
Response time: 1 s
0.1 to 99.9 s or hold
Min. power opening time: 0.5 s
No-voltage input
ON impedance:
ON residual voltage: 2 V max.
OFF impedance:
No-voltage input
ON impedance:
ON residual voltage: 1 V max.
OFF impedance:
Contacts: 5 A at 250 VAC, resistance load (cos
Transistor output: Open collector 100mA at 30 VDC max. residual voltage 2 V
max. (Approx. 1 V)
80 mA, 12 VDC !10% (5% ripple max.)
-10"C to 55"C (with no icing)
-25"C to 65"C (with no icing)
35% to 85%
Light gray
Power start: !0.01% !0.05 s max.
Control signal start: !0.005% !0.03 s max. *(rate for set value)
100 M$ min. (at 500 VDC) (between current-carrying terminal and exposed
non-current-carrying metal parts, and between non-continuous contacts)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminal and
exposed non-current-carrying metal parts) for 100 to 240 VAC type
1,000 VAC for 24VAC/12 to 24 VDC type
3 kV (between power terminals) for 100 to 240 VAC type, 1 kV for 24 VAC/12 to
24 VDC type
4.5 kV (between current-carrying terminal and exposed non-current-carrying
metal parts) for 100 to 240 VAC type, 1.5 kV for 24 VAC/12 to 24 VDC type
!2 kV (between power terminals) and !600 V (between input terminals),
square-wave noise by noise simulator (pulse width: 100 ns/1 &s, 1-ns rise)
Malfunction: 8 kV; destruction: 15 kV
Destruction
10 to 55 Hz with 0.75-mm single amplitude each in three directions
Malfunction
10 to 55 Hz with 0.5-mm single amplitude each in three directions
Destruction
294 m/s
2
Malfunction
98 m/s
Mechanical
10 million operations min.
Electrical
100,000 operations min. (5 A at 250 VAC in load resistance)
Approx. 270 g (9.6 oz)
1 k$ max. (Approx. 2 mA when 0 $)
100 k$ min.
1 k$ max. (Approx. 2 mA when 0 $)
100 k$ min.
2
(30G) each in three directions
(10G) each in three directions
H5BR
%
= 1)
161