H3G
Characteristics
Accuracy of operating time
Setting error
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Approved standards
Weight
Engineering Data
H3G-8A
Load current (A)
!2% max.
!10% max.
!2% max.
!5% max.
100 M$ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts, and
between contact-carrying and control circuit, and between contacts of different poles)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Destruction: 10 to 55 Hz with 0.75-mm double amplitude
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude
2
Destruction: 1,000 m/s
(approx. 100G)
2
Malfunction: 100 m/s
(approx. 10G)
Operating: --10"C to 55"C
Operating: 35% to 85%
Mechanical: 10,000,000 operations min.
Electrical:
See "Engineering Data."
UL (File No. E41515)
CSA (File No. LR22310) Input:
Output: H3G-8A: 7 A at 125, 250 VAC (resistive load)
SEV
Approx. 55 g
H3G-8C
100/110/120, 200/220/240 VAC (50/60 Hz)
H3G-8C: 5 A at 125, 250 VAC (resistive load)
Load current (A)