H5F
Characteristics
Accuracy of operating time
Setting error
Influence of voltage
Influence of temperature
Cyclic error
Memory protection
Insulation resistance
Dielectric strength
Noise immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Approved standards
Weight
Note: 1. The total error including the repeat accuracy, setting error, variation due to voltage change, and variation due to temperature
change is !0.01%!0.05 s max. !0.01% also indicates an error in the time interval of a set time.
2. The total time when power is not being supplied.
Operation
Operation method
Operation
Display
Number of circuits
Setting method
Minimum setting unit
Minimum set interval
Number of operations that can be
set
Note: Up to 8 ON/OFF operations are possible per day. (For pulse operation, the number is 16.)
Operation Function
Timer operation
Pulse-output
Forced ON/OFF operation
Partial operation on specified day
Note: Both the timer operation and the pulse operation cannot be programmed together with.
232
!0.01% !0.05 s max. (see note 1)
Monthly difference !15 s (at 25"C)
5 years min. (at 25"C) (see note 2)
100 M$ min. (between terminals and non-current-carrying metal parts, between operating
circuit and contact output circuit and between non-continuous contacts)
2,000 VAC, 50/60 Hz for 1 min (between terminals and non-current-carrying metal parts and
between operating circuit and contact output circuit)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
1.5 kV (square wave noise having 100 ns width, 1 ns rise time, ! polarity and 0" to 360" phase
is applied by noise simulator
Destruction: 10 to 55 Hz with 0.75-mm double amplitude
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude
2
Destruction: 300 m/s
(approx. 300G)
2
Malfunction: 100 m/s
(approx. 10G)
Operating: --10"C to 55"C (with no icing)
Operating: 35% to 85%
Mechanical: 50,000 operations min. (15 A, 250 VAC, resistive load)
50,000 operations min. (1 HP, 250 VAC, motor load)
50,000 operations min. (10 A, 250 VAC, inductive load (cos% = 0.7))
50,000 operations min. (100 W, 100 VAC, lamp load)
10,000 operations min. (300 W, 100 VAC, lamp load)
UL (File No. E41515), CSA (File No. LR22310)
H5F-B: approx. 115 g; H5F-KB: approx. 160 g; H5F-FB: approx. 130 g
Digital quartz
1. Daily operation (Multiple-day operation possible)
2. Pulse-output operation (pulse width can be set in units of 1 s from 1 to 59 s and in units of
1 min from 1 to 60 min)
3. Partial operation on specified day (one or some of operations for certain days can also be
executed on other days.)
4. Forced ON/OFF operation
1. Day, hours (a.m., p.m.), minutes (0:00 to 11:59 a.m., 0:00 to 11:59 p.m.)
2. Digital display by LCD. Character height: 8 mm
3. Digital display of present time and time schedules for operation
4. Timing chart display of present time and time schedules for operation
1 independent circuit
Key switch
1 min
1 min
16 (see note)
Controls the output according to preset of ON and OFF times (the time can be set in units of
1 min)
Produces output for a fixed duration at the preset ON time (pulse width: 1 to 59 s, or 1 to 59
min). The pulse width can be set in units of 1 s or 1 min.
Forcibly turns ON/OFF the output by a slide switch
Part of one day's operation programmed for any weekday from Sunday to Saturday can be
executed. (Convenient, for example, for executing a half-day operation on Saturday.)
H5F