H3CA
Ratings
Item
Rated supply voltage
Operating voltage range
Power consumption
Control outputs
Note: Single-phase, full-wave rectified power sources may be used for 24 to 240 VDC.
Characteristics
Accuracy of operating time
Influence of voltage
Influence of temperature
Setting error
Reset time
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Approved standards
Weight
Engineering Data
Load current (A)
110
H3CA-A/H3CA-FA
24 to 240 VAC (50/60 Hz),
12 to 240 VDC (permissible
ripple: 20% max.)
90% to 110% of rated supply
voltage
AC: approx. 2 VA
DC: approx. 2 W
3 A at 250 VAC, resistive load (cos% = 1)
!0.3% !0.05 s
!0.5% !0.05 s
H3CA-A/-FA: 0.5 s max.
H3CA-8H/-8: 0.1 s max.
100 M$ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts and
between contact and control circuit)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Destruction: 10 to 55 Hz with 0.75-mm double amplitude
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude
Destruction: 1,000 m/s
Malfunction: 100 m/s
Operating: --10"C to 55"C
Operating: 35% to 85%
Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:
100,000 operations min. (3 A at 250 VAC, cos% = 1 at 1,800 operations/h)
UL (File No. E41515), CSA (File No. LR22310), SEV
H3CA-A: approx. 110 g
H3CA-FA: approx. 190 g
Reference: A maximum current of 0.15 A can be switched at 125 VDC (cos% = 1).
Note: 1. The H3CA Series has been tested for the following: impulse voltages, noise
H3CA-8
100/110/120, 200/220/240 VAC, (50/60 Hz),
24 VDC (permissible ripple: 20% max.) (see note)
85% to 110% of rated supply voltage
AC: approx. 10 VA/1 W
DC: approx. 1 W
2
(approx. 100G)
2
(approx. 10G)
Maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases,
a life of 100,000 operations can be expected.
(via noise simulator, for L loads, and for relay oscillation), and resistance to
static electricity.
2. Minimum applicable load (P reference values):
H3CA-A(FA), H3CA-8H: 100 mA at 5 VDC
H3CA-8: 10 mA at 5 VDC
H3CA
H3CA-8H
AC: approx. 10 VA/1.5 W
DC: approx. 2 W