H3CT
Time Ranges
Series
B
C
D
E
Ratings
Rated supply voltage
Operating voltage range
Power consumption
Control outputs
Characteristics
Accuracy of operating time
Setting error
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Vibration resistance
Ambient temperature
Ambient humidity
Life expectancy
Nomenclature
Power indicator
Time unit selector
322
DIP switch setting
Multiple rated time
Time unit
x 1
sec
x 10
sec
x 1
min
x 10
min
x 3
sec
x 30
sec
x 3
min
x 30
min
x 1
min
x 10
min
x 1
hrs
x 10
hrs
x 3
min
x 30
min
x 3
hrs
x 30
hrs
200 to 240 VAC
100 to 120 VAC
(50/60 Hz)
(50/60 Hz)
85% to 110% of rated supply voltage
9.3 VA
4.4 VA
5 A at 250 VAC, resistive load (cos% = 1)
!1% FS max. (!10 ms FS in ranges of 0.5 and 1 s)
!5%
!1% (!10 ms FS in range of 0.5 and 1 s)
!2% (!10 ms FS in range of 0.5 and 1 s)
100 M$
2,000 VAC (between current-carrying metal parts and exposed non-current-carrying metal parts)
2,000 VAC (between control output terminals and operating circuit)
1,000 VAC (between contacts not located next to each other)
Destruction: 0.75-mm single amplitude each in three directions
Malfunction: 0.5-mm single amplitude each in three directions
Operating: --10"C to 55"C (with no icing)
Operating: 35% to 85%
Mechanical: 10,000,000 operations min. (at 1,800 operations/h)
Electrical:
100,000 operations min. (5 A at 250 VAC, cos% = 1, at 1,800 operations/h)
Time setting range
0.1 to 1 s
1 to 10 s
0.1 to 1 min
1 to 10 min
0.3 to 3 s
3 to 30 s
0.3 to 3 min
3 to 30 min
0.1 to 1 min
1 to 10 min
0.1 to 1 hrs
1 to 10 hrs
0.3 to 3 min
3 to 30 min
0.3 to 3 hrs
3 to 30 hrs
24 VDC
1.3 W
Scale range display windows
Time scale selector
H3CT
Maximum setting time
1 s
10 s
1 min
10 min
3 s
30 s
3 min
30 min
1 min
10 min
1 hr
10 hrs
3 min
30 min
3 hrs
30 hrs
12 VDC
90% to 110% of rated
supply voltage
1 W