STP
Specifications
Time Ranges
Rated time
5 s
10 s
30 s
60 s
180 s
6 min
10 min
30 min
60 min
180 min (see note)
6 hrs (see note)
12 hrs (see note)
24 hrs (see note)
Note: For long-time specifications with a maximum setting time of over 180 min, only the models with a moving pointer are available.
Ratings
Rated supply voltage
Operating voltage range
Power consumption
Control outputs
Note: The front panel of the timer is color-coded to identify the following supply voltage classifications:
100 to 120 V:
Blue
220 to 240 V:
Red
Other classes: Black
Characteristics
Accuracy of operating time
Setting error
Reset time
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Approved standards
Weight
Time setting range
50 Hz
0.4 to 6 s
1 to 12 s
1 to 36 s
2 to 72 s
5 to 215 s
1/6 to 7 1/6 min
1/3 to 12 min
1 to 36 min
2 to 72 min
5 to 215 min
1/3 to 7 hrs
1/2 to 14 hrs
1 to 28 hrs
100, 110, 200, or 220 VAC (50 Hz), 100/110, or 200/220 VAC (60 Hz)
85% to 110% of rated supply voltage
Approx. 5 VA
Time-limit contact: 3 A at 250 VAC, resistive load
Instantaneous contact: 1.5 A at 250 VAC, resistive load
!0.5% max. *!1% max. for the 5-s and 10-s model)
!5% max.
0.5 s max.
!1% max.
!2% max.
50 M$ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and non-current-carrying
metal parts, between control output terminal and operating circuit, and between contacts of
different polarities)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Destruction: 16.7 Hz with 4-mm double amplitude
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude
2
Destruction: 1,000 m/s
2
Malfunction: 150 m/s
(approx. 15G)
Operating: --10"C to 50"C
Operating: 35% to 85%
Mechanical: 1,000,000 operations min.
Electrical:
See "Engineering Data"
UL (File No. E52800), CSA (File No. LR22310)
Approx. 300 g
60 Hz
0.4 to 5 s
1 to 10 s
1 to 30 s
2 to 60 s
5 to 180 s
1/6 to 6 min
1/3 to 10 min
1 to 30 min
2 to 60 min
5 to 180 hrs
1/3 to 6 hrs
1/2 to 12 hrs
1 to 24 hrs
(approx. 100G)
STP
Time division
0.2 s
0.5 s
1.0 s
2.0 s
5.0 s
10.0 s
20.0 s
1.0 min
2.0 min
5.0 min
20.0 min
30.0 min
1.0 hrs
225