Test Pictures Generated By The Actas Interface Unit - Barco ACTAS 2 Owner's Manual

Table of Contents

Advertisement

ACTAS software
The test pictures can be generated from four kinds of
sources: the Interface unit of the ACTAS, a host compu-
ter, a manually controllable source and a fixed source.
Test pictures generated by the ACTAS
Interface unit
The ACTAS Interface unit has a RGB picture generator.
The generated signals are then sent to the projector
through the TEST PICTURE OUTPUT connection. The
parameters of the test pictures can be programmed with
the help of the ACTAS Control Unit and can be stored in
the 'Set-up memory blocks' of the ACTAS Control Unit.
Horizontal scan frequency of the signals
u
Range : 15.625 to 99.990kHz
u
Resolution : on the Control Unit this is programmable
in 10Hz steps, but since lines consists of 280ns
pieces, the actual resolution is about 70Hz when the
scan frequency is around 15kHz, and about 3kHz
when the scan frequency is around 100kHz.
Vertical scan frequency
u
Range: 42Hz to 150Hz
u
Resolution : on the Control Unit this is programmable
in 1Hz steps.
Sync type
u
RGsB (sync on green, non-interlacing)
u
RGB_S (sync separate, non-interlacing)
u
RGsB interlace (sync on green, interlacing)
u
RGB_S interlace (sync separate, interlacing)
Test picture patterns for evaluating results
u
Window
: also used for adjustment,
1 grey level, limited in size
u
Pluge
: useful for manually aligning the
brightness level :
the +5% rectangle should be distin-
guishable from the 0% background,
and the -5% rectangle not.
u
Vertical bar
: 8 grey levels
u
Horizontal bar : 8 greys levels
u
Gamma
: as many as possible levels
(up to 128)
u
Blocks
: 50 grey levels
u
Corners
: 1 grey level, limited in size
Note : The chosen picture pattern under the 'Edit pa-
rameters' menu is the one which will be displayed
when the ACTAS is idle, it is not the picture
pattern used for adjustments.
2-4
0% brightness on background
+5% brightness
5975636
ACTAS 2
Vertical bar
Horizontal bar
Gamma
Blocks
Corners
Pluge
-5% brightness
170297

Advertisement

Table of Contents
loading

This manual is also suitable for:

R9827961R9827968

Table of Contents