D.
Locate the lock assembly and install the two remaining machine screws (115052).
E.
With all four machine screws in place, and the lock assembly located correctly, tighten all four screws.
F.
Once the lock is correctly positioned and secured, install the two remaining mounting screws (Sheet Metal/Wood_115031)
nearest the strike opening (top and bottom) to attach the CDX-10 assembly to the door panel.

Cut the Tubes

Warning: The end of the large tube that is to be discarded must be from the plain (un-flared) end of the tube. The end of the
small tube that is to be discarded must also be from the plain (un-notched) end of the tube.
A.
Make sure that the outer tube is properly placed over the lock case tube retainer.
B.
Hold the outer tube firmly in its seated position and use a 6" scale or ruler to measure
mark the outer tube at this length.
C.
Remove the lock case assembly from the door and remove the outer tube for cutting.
D.
Assemble the saw blade and wooden saw handle provided. (To assemble the saw, grip the saw frame in a vise,
just below the neck. Drive the handle fully onto the neck. This will reduce the tendency of the handle to turn on the
saw frame when sawing.)
Note: This saw is intended only for cutting the tubes. A standard hacksaw should be used to cut the spindle.
Warning: The end of the outer tube that is to be discarded must be from the plain (un-
flared) end of the tube. The end of the inner tube that is to be discarded must also be from
the plain (un-notched) end of the tube.

DKX-10/DKX-19 High Security Lock Installation (Continued)

G.
Place the inner tube into the lock case tube retainer. (Ensure that the cutout
in the tube aligns with the cables and allows the tube to seat completely in
the tube retainer.)
H.
Refer to Figure 4. Feed the cables through the outer, larger, tube starting from
the flared end of the tube.
I.
Seat the tube into position on the tube retainer on the back of the lock case
assembly. (Be careful to keep the cables pulled taut while seating the tube to
avoid pinching damage to them.)
Alternate Method: Depending on the width of the door, it may be easier to insert the
non-flared end of the outer tube through the spindle hole from the inside of the door and feed
the cables through the tube, and then seat the flared end of the tube on the tube retainer.
Figure 5
6
Seat Inner Tube in Retainer