OPERATING
INSTRUCTIONS
X-10
TM
Type 1F
HIGH SECURITY ELECTRONIC LOCK

Advertisement

Table of Contents
loading

Summary of Contents for Kaba Mas X-10

  • Page 1 OPERATING INSTRUCTIONS X-10 Type 1F HIGH SECURITY ELECTRONIC LOCK...
  • Page 2: Table Of Contents

    Dialing Methods  2 To Power the Lock  2 Dialing A Combination 2 Open and Close the X-10 (Factory Combination) ��������������������������� 4 To Open the Lock (Using the Factory Combination)  4 To Close the Lock  4 X-10 Lock Setup �������������������������������������������������������������������������������� 5...
  • Page 3: Introduction

    The microprocessor in the lock recognizes a number as part of a combination when you change dialing direction (See the section on Dialing the X-10) Note: The lock is shipped preset to operate in the Single Combination Mode with a Default Factory Combination of 50-25-50.
  • Page 4: Dialing The X-10

    DIALING A COMBINATION The X-10 recognizes a number as being part of a combination when you stop on that number and then reverse dialing directions When dialing a combination, you will dial left for the 1st...
  • Page 5 The screen goes blank before the lock bolt is retracted b. A lightning bolt is displayed Caution: An X-10 lock will initiate a timed lockout of 3 minutes when ten consecutive wrong combinations have been dialed. Each additional unsuccessful attempt to open the lock will initiate another timed lockout.
  • Page 6: Open And Close The X-10 (Factory Combination)

    Close The X-10 (factory Combination) If you have not read the section on “Dialing the X-10”, it is important that you do so before proceeding� Note: The lock is shipped preset to operate in the Single Combination Mode with a Default Factory Combination of 50-25-50.
  • Page 7: X-10 Lock Setup

    Mode and Change CoMbInaTIons Use the Change Key (See Figure 2) provided with your X-10 to set the desired operating mode and combinations If at any time during the process you see the Key and Lightning...
  • Page 8 2 Release the container locking bolts if necessary (Different containers will have different release mechanisms) 3 Insert the Change Key into the change key holes on the back of the lock (See Figure 3) 4 Dial left (CCW) until the Change Key appears in the upper right hand corner of the display Caution: Release container locking bolts if necessary.
  • Page 9 If Selection = 01, Single Combination Mode: 1 Dial right (CW) until the symbol eC (enter Combination) appears 2 Dial the new combination as if dialing a combination to open the lock; ie, left (CCW) to dial the first number, right (CW) to dial the second number, left (CCW) to dial the third number EXAMPLE: Set Combination to 30-60-90 Dial left to the first number, 30.
  • Page 10: If You Lock The Change Key In The Safe

    IF YOU LOCK THE CHANGE KEY IN THE SAFE If the door of your container is shut and the X-10 is accidentally locked with the Change Key still inserted in the back of the lock, you can recover with the following procedure 1 Allow the lock to power down (After 40 seconds, the display will go blank) 2 Dial right (CW) until lock is “powered”...
  • Page 11: Using The X-10

    USING THE X-10 If you have not read the section on “Dialing the X-10”, it is important that you do so before proceeding� SINGLE COMBINATION MODE In this mode the X-10 functions much like a standard combination lock. It will open any time the three-number combination is correctly dialed.
  • Page 12: Supervisory/Subordinate Mode

    Dial left to third number, 75 Stop 3 Dial right (CW) Ul (Unlocked) is displayed indicating that the Subordinate Operator can now open the lock using only the Subordinate Combination The X-10 will now operate as if it were in a single combination mode...
  • Page 13: Correct Method Of Closing/Relocking Container

    To Lock Up (LU) Supervisory Operator: 1 Dial left (CCW) until lock is “powered” 2 Dial the Supervisory Combination as if dialing a combination to open the lock; ie, left (CCW) to dial the first number, right (CW) to dial the second number, left (CCW) to dial the third number eXaMPle: Combination = 25-50-75 Dial left to first number, 25 Stop...
  • Page 14: Audit Features Of The Lock And Firmware Level

    The loCK The X-10 lock tracks the number of successful openings for the lifetime of the lock; It tracks the number of consecutive unsuccessful attempts, it will alert you upon lock power up if there...
  • Page 15: Guide To Symbols

    gUIde To sYMbols Blank Display Lock is powered Enter Change Combination down Open Right Pull Out Change Key Lightning Bolt Confirm Combination or Incorrect Combination(s) Combination Dialed Lightning Bolt Enter first Combination with Error Count Incorrect Combination Dialed xx times. (The error count is only Enter second Combination displayed when there have...
  • Page 16: Document Number 5390512

    Notice: The information in this manual is subject to change without notice and does not represent a commitment on the part of Kaba Mas. Kaba Mas shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance or use of this material.