Kaba Mas LA GARD COMBOGARDPRO 39E Setup Instructions

Kaba Mas LA GARD COMBOGARDPRO 39E Setup Instructions

Electronic combination lock - keypad only setup instructions

Advertisement

Quick Links

KEYPAD ONLY SETUP INSTRUCTIONS
ComboGard Pro locks can either be configured using the ComboGard Pro Setup software or through
a series of keypad commands. This document will cover configuring the lock using the keypad
commands ONLY.
The ComboGard Pro Lock has three states of operation: Factory Default, Manual Setup, and
Active. ComboGard Pro locks are shipped from LA GARD in Factory Default state without Users or
features enabled.
Factory Default: The Lock must be in the Factory Default state to be programmed by the PC
software.
Factory mode functions as follows:
• 1 key – When pressed, will open the Lock.
• 0 key – When pressed, prompts the ComboGard Pro Setup software to send the configuration
settings to the Lock.
OR if pressed and held, places the Lock into Manual Setup.
• All other keys perform no function.
Manual Setup: The Lock can be configured using the keypad only.
Active: To activate the Lock and freeze the configuration, the Manager combination MUST
be changed.
WARNING: Add all required Users and complete Setup Configuration before changing the Manager's
default combination from 5-5-5-5-5-5. Once the combination is changed, NO ADDITIONAL USERS
can be added.

PROGRAMMABLE LOCK FEATURES

MODES (Multiple Modes may be selected.)
• Silent Alarm (Alarm Box Required)
If enabled, this option will send a signal to an outside alarm system through the LA GARD
Alarm Box.
• Dual Mode
If enabled, two combinations will be required to operate the Lock.
The Manager and one additional User must be active.
• Time Delay Override
If enabled, User 9 can override delay period.
User 9 must be active.
EXTERNAL SIGNALS (Alarm Box Required - P/N 2789NC. Only one External Signal type may
be selected.)
An external input signal to the Alarm Box will either disable the Lock from opening, override the time
delay, or enable the remote override depending on the selection programmed for External Signals.
• External Signal disables Lock opening with valid combination.
NOTE: When configuring the ComboGard Pro Lock using the keypad only, the Disable Opening
option is enabled by default and cannot be changed.
OR External Signal overrides Time Delay. (This option is ONLY available if enabled using Setup
software.)
OR External Signal enables the Remote Override. (This option is ONLY available if enabled using
Setup software, and with Lock code level 39E v1.09 or higher.)
(P/N) 735.028 Rev M • 11/14
COMBOGARDPRO
39E Electronic Combination Lock
© copyright 2006-2014
Kaba Mas LLC
Page 1 of 8

Advertisement

Table of Contents
loading

Summary of Contents for Kaba Mas LA GARD COMBOGARDPRO 39E

  • Page 1 OR External Signal enables the Remote Override. (This option is ONLY available if enabled using Setup software, and with Lock code level 39E v1.09 or higher.) Kaba Mas LLC (P/N) 735.028 Rev M • 11/14 © copyright 2006-2014 Page 1 of 8...
  • Page 2 • To open a container with a Dead or Spring Bolt Lock, turn the keypad or dial to retract the bolt and open the door. • When closing a container, verify that it has been secured. Kaba Mas LLC (P/N) 735.028 Rev M • 11/14 © copyright 2006-2014...
  • Page 3 1. Enter the default Manager combination (5-5-5-5-5-5) and hold down last digit of combination until lock double signals twice release and the LED stays on. 2. PRESS 8. Kaba Mas LLC (P/N) 735.028 Rev M • 11/14 © copyright 2006-2014...
  • Page 4 2. PRESS 9. 3. Enter two-digit Delay Period value (00 to 99 minutes) followed by the two-digit Open Period value (00 to 19 minutes). Kaba Mas LLC (P/N) 735.028 Rev M • 11/14 © copyright 2006-2014 Page 4 of 8...
  • Page 5 5. Disconnect Reset Box. The Lock is now in Factory mode, and is ready to be configured by the PC Software or through the keypad. Kaba Mas LLC (P/N) 735.028 Rev M • 11/14 © copyright 2006-2014 Page 5 of 8...
  • Page 6 NOTES: Kaba Mas LLC (P/N) 735.028 Rev M • 11/14 © copyright 2006-2014 Page 6 of 8...
  • Page 7 NOTES: Kaba Mas LLC (P/N) 735.028 Rev M • 11/14 © copyright 2006-2014 Page 7 of 8...
  • Page 8 Notice: The information in this manual is subject to change without notice and does not represent a commitment on the part of Kaba Mas. Kaba Mas shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance or use of this material.

This manual is also suitable for:

La gard combogard pro 39e

Table of Contents