OPERATING
INSTRUCTIONS
TM
X-09
Type 1F
HIGH SECURITY ELECTRONIC LOCK

Advertisement

Table of Contents
loading

Summary of Contents for Kaba Mas X-09

  • Page 1 OPERATING INSTRUCTIONS X-09 Type 1F HIGH SECURITY ELECTRONIC LOCK...
  • Page 2: Table Of Contents

    ABLE OF ONTENTS ................1 NTRODUCTION Lock On Back Cover ................ 1 X-09 ...............2 IALING THE Dialing Methods ................2 To Power the Lock ................2 Dialing A Combination ..............2 X-09 (F ) ......4 PEN AND LOSE THE ACTORY OMBINATION To Open the Lock (Using the Factory Combination) ......
  • Page 3: Introduction

    The microprocessor in the lock recognizes a number as part of a combination when you change dialing direction. (See the section on Dialing the X-09.) Note: The lock is shipped preset to operate in the Single Combination Mode with a Default Factory Combination of 50-25-50.
  • Page 4: Dialing The X-09

    DIALING A COMBINATION The X-09 recognizes a number as being part of a combination when you stop dialing on that number and then reverse dialing directions. When dialing a combination, you will dial left for the 1st two digits of the combination, dial right for the second two digits, and then dial left again for the last two digits.
  • Page 5 B. A lightning bolt is displayed. Caution: An X-09 lock will initiate a timed lockout of 3 minutes when ten consecutive wrong combinations have been dialed. Each additional unsuccessful attempt to open the lock will initiate another timed lockout. If the number of consecutive unsuccessful attempts reaches fi...
  • Page 6: Open And Close The X-09 (Factory Combination )

    PEN AND LOSE THE FACTORY COMBINATION If you have not read the section on “Dialing the X-09”, it is important that you do so before proceeding. Note: The lock is shipped preset to operate in the Single Combination Mode with a Default Factory Combination of 50-25-50.
  • Page 7: Setup

    SET OPERATING MODE AND CHANGE COMBINATIONS Use the Change Key (Figure 2) provided with your X-09 to set the desired operating mode and combinations. If at any time during the process you see the Key and Lightning Bolt symbols displayed, stop the sequence and return to Step 4.
  • Page 8 If you have lost or forgotten the combination(s) and are using the serial number method to complete this process, simply dial an incorrect combination to get a lightning bolt display. The error must be created before inserting the Change Key, and the Change Key must be inserted while the lightning bolt is displayed. See next step.
  • Page 9 Note: If the correct combination is not displayed, you may pull out the change key and the lock will allow you to reset the combination. You must pull out the change key while the display is still fl ashing. When EC appears, insert the change key again and dial the desired combination.
  • Page 10: If You Lock The Change Key In The Safe

    IF YOU LOCK THE CHANGE KEY IN THE SAFE If the door of your container is shut and the X-09 is accidentally locked with the Change Key still inserted in the back of the lock, you can recover with the following procedure.
  • Page 11: Using The X-09

    If you have not read the section on “Dialing the X-09”, it is important that you do so before proceeding. SINGLE COMBINATION MODE In this mode the X-09 functions much like a standard combination lock. It will open any time the three-number combination is correctly dialed. 1. Dial left (CCW) until lock is “powered”.
  • Page 12: Supervisory/Subordinate Mode

    Dial left to third number, 75. Stop. 3. Dial right (CW). UL (UnLocked) is displayed indicating that the Subordinate Operator can now open the lock using only the Subordinate Combination. The X-09 will now operate as if it were in a single combination mode.
  • Page 13: Correct Method Of Closing/Relocking Container

    To Lock Up (LU) Supervisory Operator: 1. Dial left (CCW) until lock is “powered”. 2. Dial the Supervisory Combination as if dialing a combination to open the lock; i.e., left (CCW) to dial the fi rst number, right (CW) to dial the second number, left (CCW) to dial the third number.
  • Page 14: Audit Features Of The Lock

    UDIT EATURES OF THE The X-09 lock tracks the number of successful openings for the lifetime of the lock. It also tracks the number of consecutive unsuccessful attempts and will alert you upon lock power up if there have been 3 or more consecutive unsuccessful attempts to open the lock. The lock bolt must be extended and the lock allowed to power down prior to obtaining an audit count of any type.
  • Page 15: Guide To Symbols

    UIDE TO YMBOLS Blank Display Lock is powered down. Open Right Lightning Bolt Incorrect Combination Dialed. (When this symbol appears in the upper left corner of the display, dial the correct combination.) Lightning Bolt with Error Count Incorrect Combination Dialed xx times. (The error count is only displayed when there have been 3 or more consecutive unsuccessful attempts.) Unlocked Lock Up...
  • Page 16 OTES...
  • Page 17 Notice: The information in this manual is subject to change without notice and does not represent a commitment on the part of Kaba Mas. Kaba Mas shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance or use of this material.