4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT
4.10.5 RFID Module Settings
After installing the RFID Module on the printer, configure the RFID module settings in the printer system
mode.
 How to enter the System Mode
Power OFF
Turn on the printer while holding
down [FEED] & [PAUSE] or
[MODE].
SYSTEM MODE
<1>DIAG.
<2>PARAMETER SET
<3>ADJUST SET
<4>TEST PRINT
 Contents of the RFID Menu
Menu
Sub menu
RFID
TEST
MODULE
RETRY
UHF SETTING
OTHER
 Key functions in the system mode
Key
[MODE]
[CANCEL] or
[FEED]+[RESTAR]
[ENTER] or [PAUSE]
[UP] or [RESTART]
[DOWN] or [FEED]
[LEFT]
[RIGHT]
Press [DOWN] until
"<10>RFID" is
highlighted.
Parameter
ID READ
MODULE TYPE
COUNTRY
TAG
RF CHANNEL
ADJ RETRY POSITION
ISSUE RETRY LABELS
READ RETRY
WRITE RETRY
POWER LEVEL
Q VALUE
AGC THRESHOLD
WRITE AGC THRESHOLD
WRITE RETRY MIN AGC
TAG CHECK
MULTI WRITE
CARRIER SENSE
Function
Returns to the mode menu screen.
Returns to the upper hierarchy.
Displays a next screen.
Saves the setting and returns to the upper hierarchy.
Moves the cursor upward.
Increases a value.
Moves the cursor downward.
Decreases a value.
Moves the cursor to the left.
Moves the cursor to the right.
4.10 UHF RFID KIT (B-EX700-RFID-U4-US/EU/CN-R)
SYSTEM MODE
<7>INTERFACE
<8>BASIC
<9>FOR FACTORY
<10>RFID
4-62
EO18-33027
(Revision Date: Sept. 5, 2014)
Press [ENTER].