10. RFID ANALYZE TOOL
4. When the "CommSetting" screen appears, perform the serial port or LAN setting in accordance with the
settings of the B-EX4T/EX6T printer.
Baudrate: 2400, 4800, 9600, 19200, 38400, 115200
Parity: NONE, EVEN, ODD
Flow control:
NOTES:
1. Choose the port to which the printer is connected.
2. Choose "NON" for the Flow control of the RFID Analyze Tool. However, any flow control code of the
printer is acceptable.
3. The data bit for the Analyze Tool is fixed to 8. Make sure the data length for the B-SX4T/SX5T printer
is set to 8 bits.
4. The command flame for the Analyze Tool is "{ | }". Make sure the control code for the B-SX4T/SX5T
printer is set to "AUTO" or "{ | }"..
5. When the printer and the PC are connected via LAN, a printer IP address and socket port number need
to be entered.
Default Printer IP Address: 192.168.10.20, Socket Port No.: 8000
Port: COM1 to COM9
Data bit: 8 bit
Stop bit: 1, 2
NON, XON, XON/XOFF,
RTS/CTS+XON/XOFF
Printer IP Address
Socket Port No.
10- 15
EO18-33027
10.4 Operating Procedure