Class A Chimney/Masonry Chimney Conversion - kozy heat CALLAWAY 50 MV Installation And Operation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

7.7 Class A Chimney/Masonry
Chimney Conversion
This appliance is approved to be adapted for Class A/Masonry
Chimney conversion with kits utilizing a 4" (102mm) flexible exhaust
by any vent manufacturers listed in section 7.1, APPROVED VENT
SYSTEMS on page 44.
Before conversion, have the existing installation inspected by a
qualified chimney sweep or professional installer. The existing
chimney system must be in serviceable condition, and functionally
sound. Before proceeding with following installations, check with
local building jurisdiction to verify this type of installation is allowed
in your area.
Follow DIAG. 4 for allowable venting configurations for installation
in existing through-the-ceiling, Class A/Masonry chimney. Route the
exhaust gases and intake air through the existing Class A/Masonry
chimney.
7.7.1 4" Flex Pipe Venting Configurations
IMPORTANT: Horizontal vent sections require at least 1/4" (6mm) rise
for every 12" (305mm) of travel.
IMPORTANT: The vent heat shield assembly must be installed when
incorporating minimum horizontal venting off the top of the appliance.
IMPORTANT: Care should be taken when installing flexible pipe to avoid
a tight bend that may cause abrasion or damage to the flexible pipe.
The vent option listed below allow for a minimum of 0" (0mm) to a
maximum of 24" (610mm) horizontal run using rigid or flexible pipe.
(i) Minimum / Maximum Vertical Terminations:
45° horizontal elbow + reducer + retro connector + 10' (3.05m)
minimum length of 4" aluminum flexible pipe / 50' (15.24m)
maximum length of 4" aluminum flexible pipe + top adapter +
termination cap
HUSSONG MFG. CO., INC.
KOZY HEAT FIREPLACES

Class A Chimney/Masonry Chimney Conversion

DIAG. 4 4" FLEX PIPE CHIMNEY CONVERSION
(A) 45° Elbow
(D) Top Adapter
(B) Reducer
(E) Termination Cap
(C) Retro Connector
E
D
E
D
B
A
C
SECTION 7 VENTING
50'
(15.24m)
10'
(3.05m)
51
#CLW-50-MV
R.1 October 2021