HORIZONTAL VENT HEAT SHIELD
IMPORTANT: The horizontal vent heat shield must be installed when using a 90-degree elbow to horizontally position the vent system.
This includes any corner installation.
CAUTION: This gas appliance must not be connected to or joined with any other chimney flue serving another appliance.
1.
Loosen, but do not remove center three screws on top of fireplace.
2.
Bend horizontal heat shield at perforation to a 90° angle. Slide (3) slots on horizontal vent heat shield under loosened screws.
3.
Re-tighten screws.
Figure 20a
HORIZONTAL VENTING
NOTE: Horizontal sections require 1/4" (6mm) rise for every 12" (305mm) of travel.
TYPICAL CORNER INSTALLATION 5" X 8"
90° elbow + horizontal pipe+ termination cap.
(Horizontal Vent Heat Shield required).
VENTING DIMENSIONS FOR MINIMUM CORNER
INSTALLATIONS USING 5" x 8"
Vent Opening Dimensions: 12-1/2" (318mm) H x 10-7/8" (276mm)
From Floor or Hearth to Vent Opening Center: 37-7/8" (962mm)
From Corner to Vent Opening Center: 15-7/8" (403mm)
VENTING
ATTACHMENT SCREWS
PAGE 20
HORIZONTAL TERMINATION CAP
PIPE
90° ELBOW
Figure 20b