HORIZONTAL VENT HEAT SHIELD
The horizontal vent heat shield must be installed when using a 90-degree elbow to horizontally position the vent system.
IMPORTANT
This includes any corner installation.
1.
Loosen, but do not remove center three screws on top of fireplace.
2.
Bend horizontal heat shield at perforation to a 90° angle. Slide (3) slots on horizontal vent heat shield under loosened screws.
3.
Re-tighten screws.
ATTACHMENT SCREWS
Figure 20a
HORIZONTAL VENTING
NOTE
Horizontal sections require 1/4" (6mm) rise for every 12" (305mm) of travel.
TYPICAL CORNER INSTALLATION 5" X 8"
90° elbow + horizontal pipe+ termination cap.
(Horizontal Vent Heat Shield required).
VENTING DIMENSIONS FOR MINIMUM CORNER
INSTALLATIONS USING 5" x 8"
Vent Opening Dimensions: 12-1/2" (318mm) H x 10-7/8" (276mm)
From Floor or Hearth to Vent Opening Center: 37-7/8" (962mm)
From Corner to Vent Opening Center: 15-7/8" (403mm)
VENTING
TERMINATION CAP
90° ELBOW
Figure 20b