ISO 15693 host commands
9.2 Supported ISO 15693 host command for ISO 15693 transponders
Command code Function
0x22
Lock Multiple
Blocks
0x23
Read Multiple
Blocks
2)
0x24
Write Multiple
Blocks
0x25
Select
0x26
Reset to Ready ✓
0x27
Write AFI
0x28
Lock AFI
0x29
Write DSFID
0x2A
Lock DSFID
0x2B
Get System
Information
0x2C
Get Multiple
Block Security
Status
0xA3
Inventory Read
Multiple Blocks
0xAB
Inventory Get
System Infor-
mation
0xAC
Inventory Get
Multiple Block
Security Status
0xA2
Write 2 Blocks
0xA3
Lock 2 Blocks
1) The WR-OPTION is set automatically by the reader if the WR-OPTION parameter in the "CFG4 transponder parameters"
is set to "00: specified automatically". When using the non-addressed mode, the WR-OPTION must be set manually to
"WR-OPTION = 1".
Note
Effects
"Write_2_Blocks" command and the "Lock_2_Blocks" command are used by the reader
automatically. This only takes effect if the block address starts with an even address.
If an odd number of blocks are written/locked, the "Write_2_Blocks"/"Lock_2_Blocks"
command is combined with the "Write Single Block"/"Lock Single Block" command.
96
Mode
-
-
-
-
-
-
-
-
-
-
-
Configuration Manual, 09/2014, C79000-G8976-C377-01
Comment
WR-OPTION = 1
1)
DB-SIZE = 4
DB-SIZE = 4
WR-OPTION = 1
1)
-
-
WR-OPTION = 1
1)
WR-OPTION = 1
1)
WR-OPTION = 1
1)
WR-OPTION = 1
1)
-
-
-
-
-
WR-OPTION = 11)
WR-OPTION = 11)