Table 8- 22
REQUEST-DATA
Byte
Content
Table 8- 23
RESPONSE-DATA
Byte
Content
Name
Description
MODE
Bit
Function
Function
ADR
UID
Write-protected serial number of the transponder. This UID is only required in addressed mode.
AFI
Application Family Identifier of the transponder
ISO15693
ISO 15693 error code of the transponder response. This byte is only available if STATUS = {0x95}.
ERROR
8.13
[0x2B] Get System Information
This command reads system information from a transponder.
Note
Only ISO 15693 transponders
This command is only available for ISO 15693 transponders.
Table 8- 24
REQUEST-DATA
Byte
Content
RF290R
Configuration Manual, 09/2014, C79000-G8976-C377-01
6
0x2A
ISO15693 ERROR
7
6
0
0
Description
b000
not addressed
b001
addressed
b010
selected
6
0x2B
Protocols for ISO 15693 host commands
7
MODE
7
5
4
3
0
0
0
7
MODE
8.13 [0x2B] Get System Information
(8 ... 15)
UID
-
2
1
ADR
(8 ... 15)
UID
0