RF290R
Configuration Manual, 09/2014, C79000-G8976-C377-01
Transponder status
No transponder:
No transponder within the detection field of the reader
Transponder in detection field has been switched to silent
Disruption in communication between reader and transponder. The reader
can no longer detect the transponder.
incorrect data:
CRC16 checksum error in the received data
Write error:
Plausibility test of written data failed:
Attempt to write to a read-only area (only I-CODE1 and Tag-it RF transpond-
ers)
Distance between transponder and reader antenna too great
Attempt to write during excessive ambient noise
Address error:
The requested data is outside the logical or physical address range of the tran-
sponder:
The address is outside the maximum address range of the transponder.
The address is outside the configured address range of the transponder.
wrong transponder type:
This command is not supported by this transponder:
A specific command is not supported by the transponder.
Parameter status
EEPROM error:
EEPROM of the reader cannot be written to
Before the write procedure in the EEPROM, a parameter checksum error
occurred.
Parameter outside the valid range:
Valid parameter range exceeded
Login required:
Access to the configuration without first logging in
Login error:
Attempt to log in with the wrong password
Read protection:
Configuration block reserved for future use
Write protection:
Configuration block reserved for future use