Command code Function
-
-
0x01
Inventory
0x02
Stay Quiet
0x22
Lock Multiple
Blocks
0x23
Read Multiple
Blocks
2)
0x24
Write Multiple
Blocks
0x25
Select
0x26
Reset to Ready -
0x27
Write AFI
0x28
Lock AFI
0x29
Write DSFID
0x2A
Lock DSFID
0x2B
Get System
Information
0x2C
Get Multiple
Block Security
Status
1) The WR-OPTION is set automatically by the reader if the WR-OPTION parameter in the "CFG4 transponder parameters"
is set to "00: specified automatically". When using the non-addressed mode, the WR-OPTION must be set manually to
"WR-OPTION = 1".
2) Reading multiple blocks in non-addressed mode is only possible if the "Read mode" parameter in CFG4 is set to "b01:
read once".
9.2.18
Texas Instruments (Tag-it HFI Plus)
IC manufacturer identifier: 0x07
Chip ID: 0h = 0000xxxxb or 8h = 1000xxxxb (bits 47 - 44 of UID)
Table 9- 25
Number of blocks
Block size
Command code Function
-
-
0x01
Inventory
0x02
Stay Quiet
RF290R
Configuration Manual, 09/2014, C79000-G8976-C377-01
9.2 Supported ISO 15693 host command for ISO 15693 transponders
Mode
not addressed
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Memory arrangement 64 × 4 bytes = 2 Kbits user data
Mode
not addressed
-
-
ISO 15693 host commands
addresses
Selection
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
64 (user range: 0 ... 63)
4 bytes
addresses
Selection
-
-
-
Comment
-
-
-
WR-OPTION = 1
1)
DB-SIZE = 4
DB-SIZE = 4
WR-OPTION = 1
1)
-
-
-
-
-
-
-
-
Comment
-
-
-
95