5.8
CFG7-10: Reserved
The configuration blocks CFG7 to CFG10 are reserved for later use.
Byte
0
Content
0x00
Default
-
Byte
7
Content
0x00
Default
-
5.9
CFG11: Read mode - read data
The parameters of the CFG11 configuration block contain settings for an automatic mode of
the reader. To activate an automatic mode of the reader (such as "Buffered Read Mode" or
"Scan Mode"), the relevant bit must be set in the "READER-MODE" register of the
configuration block "CFG1: Interface". It is useful to activate "Anticollision" in CFG5 if there is
a large or unknown number of transponders in the antenna field. The automatic mode of the
reader can be used in the multiplex mode of the antenna. The parameters for this function
need to be configured in "CFG15: Antenna multiplexing".
Byte
0
Content
TR-DATA-1
Default
0x01
Byte
7
Content
0x00
Default
-
RF290R
Configuration Manual, 09/2014, C79000-G8976-C377-01
1
2
0x00
0x00
-
-
8
9
0x00
0x00
-
-
1
2
TR-DATA-2
TR-DATA-3
0x00
0x00
8
9
DB-N
0x0001
3
4
0x00
0x00
-
-
10
11
0x00
0x00
-
-
3
4
BANK
0x03
10
11
EAS-MODE
D-START
0x00
0x00
Configuration parameters (CFG)
5.8 CFG7-10: Reserved
5
0x00
-
12
0x00
-
5
DB-ADR
0x0000
12
D-LGT
0x0004
6
0x00
-
13
0x00
-
6
0x00
-
13