Download Print this page

Siemens SIMATIC RF290R Configuration Manual page 83

Advertisement

Command code Function
0x2B
Get System
Information
0x2C
Get Multiple
Block Security
Status
1) The WR-OPTION is set automatically by the reader if the WR-OPTION parameter in the "CFG4 transponder parameters"
is set to "00: specified automatically". With one request, up to two blocks can be written with data.
2) The user-specific Read Multiple Blocks Unlimited [0xA3] commands are used automatically by the reader. In the non-
addressed mode, only one or two blocks can be read and the DB block size parameter in the "CFG4 transponder pa-
rameters" must be set to 8.
9.2.5
Fujitsu (MB89R119)
IC manufacturer identifier: 0x08
Chip ID: 2h = 00000010b (bit 47 - 40 of UID)
Table 9- 10
Number of blocks
Block size
Command code Function
-
-
0x01
Inventory
0x02
Stay Quiet
0x22
Lock Multiple
Blocks
0x23
Read Multiple
Blocks
0x24
Write Multiple
Blocks
1)
0x25
Select
0x26
Reset to Ready ✓
0x27
Write AFI
0x28
Lock AFI
0x29
Write DSFID
0x2A
Lock DSFID
RF290R
Configuration Manual, 09/2014, C79000-G8976-C377-01
9.2 Supported ISO 15693 host command for ISO 15693 transponders
Mode
Memory arrangement 64 × 4 bytes = 2 Kbits
Mode
not addressed
-
-
-
-
ISO 15693 host commands
64 (user range: 0 ... 57)
4 bytes
addresses
Selection
-
-
-
-
-
-
Comment
-
-
Comment
-
-
-
WR-OPTION = 0
or 1
Security status is
always 0x00
WR-OPTION = 0
or 1
-
-
WR-OPTION = 0
or 1
WR-OPTION = 0
or 1
-
-
83

Advertisement

loading